Difference between revisions of "Effective Roof Area, (A)"

From flowpedia.com
Jump to: navigation, search
(Created page with "*According to BS EN 12056-3, it is the surface area of roof where in with/ without wind driven rain is considered. == Wind driven rain == *'''Without''' Where no allowance...")
 
Line 2: Line 2:
  
  
== Wind driven rain ==
+
== Without Wind driven rain ==
*'''Without'''
 
  
 
Where no allowance is made for wind, the Effective Roof Area (A) shall be calculated from the equation;
 
Where no allowance is made for wind, the Effective Roof Area (A) shall be calculated from the equation;
"A=" L_"R" ×B_"R"
 
where
 
A is the effective roof area, in square metres ("m" ^2 );
 
L_"R"  is the length of roof to be drained, in metres (m);
 
B_"R"  is the width of roof from gutter to ridge, in metres (m).
 
  
*'''With'''
+
<math>A=L_R \times B_R</math>
 +
 
 +
where;
 +
 
 +
<math>A</math> is the effective roof area, in square metres <math>(m^2)</math>;
 +
 
 +
<math>L_R</math> is the length of roof to be drained, in metres <math>(m)</math>;
 +
 
 +
<math>B_R</math> is the width of roof from gutter to ridge, in metres <math>(m)</math>.
 +
 
 +
 
 +
== With Wind driven rain ==
  
 
Where allowance is made for wind, the effective roof area shall be calculated as follows;
 
Where allowance is made for wind, the effective roof area shall be calculated as follows;
 +
 +
{| class="wikitable"
 +
!colspan="6"|Effective impermeable roof area
 +
|-
 +
|'''Allowance to be made for the effect of wind'''
 +
|'''Effective impermeable roof area, <math>A m^2</math>'''
 +
|-
 +
|Wind driven rain, 26° to vertical
 +
|<math>A = L_R(B_R+\frac{H_R}{2})</math>
 +
|-
 +
|Rain perpendicular to roof (i.e. surface area of roof used)
 +
|<math>A = L_R \sdot T_R</math>
 +
|-
 +
|colspan="2"|'''NOTES:'''
 +
|-
 +
|colspan="2"|<math>L_R</math> is the length of roof to be drained, in metres (m);
 +
<br /><math>B_R</math> is the plan width of roof from gutter to ridge, in metre (m);

Revision as of 13:04, 25 May 2017

  • According to BS EN 12056-3, it is the surface area of roof where in with/ without wind driven rain is considered.


Without Wind driven rain

Where no allowance is made for wind, the Effective Roof Area (A) shall be calculated from the equation;

A=L_R \times B_R

where;

A is the effective roof area, in square metres (m^2);

L_R is the length of roof to be drained, in metres (m);

B_R is the width of roof from gutter to ridge, in metres (m).


With Wind driven rain

Where allowance is made for wind, the effective roof area shall be calculated as follows;

Effective impermeable roof area
Allowance to be made for the effect of wind Effective impermeable roof area, A m^2
Wind driven rain, 26° to vertical A = L_R(B_R+\frac{H_R}{2})
Rain perpendicular to roof (i.e. surface area of roof used) A = L_R \sdot T_R
NOTES:
L_R is the length of roof to be drained, in metres (m);


B_R is the plan width of roof from gutter to ridge, in metre (m);