Catchpits
Revision as of 18:55, 10 April 2017 by Joceil.infante (talk | contribs) (Created page with "'''Catchpits''' are chambers on surface water drains and sewers installed to retain silt and constructed as manholes but without benching. They are also often used on subsoil...")
Catchpits are chambers on surface water drains and sewers installed to retain silt and constructed as manholes but without benching. They are also often used on subsoil drains, especially at the point of connection with a surface water drain or sewer. The chamber floor is usually 450 mm below the invert of the outlet to form a sump and the invert of the inlet is usually 25 mm above the invert of the outlet to form a cascade for improved hydraulic efficiency.
References:
- BS EN 752:2008 Drain and sewer systems outside buildings
- http://fpmccann.co.uk/news/suds-storage-system-uses-fp-mccann-dn1500-wide-wall-catch-pit
- http://www.traceyconcrete.com/site/catchpits-2
- http://infocouncil.aucklandcouncil.govt.nz/Open/2014/12/INF_20141203_AGN_4792_AT.htm
- http://www.pavingexpert.com/drain03.htm